Dräger X-am® 2500 Multi-Gas Monitor
         
DURABLE ELECTROCHEMICAL SENSORS
Fully developed, high performance Dräger sensors in an extra small format for CO, H2S, O2, SO2 and NO2 gases enable safe use in industry, mining and in refineries. The impressive hydrogen sulphide sensor has a high resolution, so it can reliably measure even very low workplace limits. The non-consumptive and lead-free sensor for oxygen is characterized by an especially long service life of more than 5 years. Our CO and H2S sensors also have this long service life expectation, so they contribute to especially low operating costs.
 
MAXIMUM SAFETY
The Dräger X-am 2500 has Ex approval for zone 0, so it is clearly designed for very high user safety in areas subject to explosion hazard. The functional design ensures that gas can enter from above and from the side – even if the instrument is inside a pocket or if the front gas entry is accidentally covered.

MAINTENANCE: FAST, EASY, INEXPENSIVE
From functional test to complete docu- mentation, users have access to practical solutions that provide safety for implemen- tation at any time. The Dräger Bump Test
Station,
D2500
POISON RESISTANT EX SENSOR
The innovative, catalytic Ex sensor is im- pressive due to its high resistance to silicone and hydrogen sulphide. Together with the high degree of drift stability, this resistance enables an extraordinarily long service life of more than 4 years. Its high sensitivity with
regard to flammable gases and vapours is confirmed by technical approval for measuring according to
 
which does not require a local power source, and the automatic Dräger X-dock testing and calibration station for comprehensive equipment management are ideal system additions that save time and effort. Together with the Dräger X-dock, the high quality Dräger sensors enable quick bump tests of 8 to 15 seconds1) with very low gas consumption. This signi- ficantly reduces your equipment operating costs.
   
IEC/EN 60079-29-1 from methane to nonane. This approval also demonstrates the suitability of this instrument for use in refineries and in the chemical industry as well.
 
1) With standard sensors: CH4, O2, CO, H2S
   
         
DIFFUSION OR PUMP
For clearance measurements for tanks and shafts or when searching for leaks, an optional external pump with a hose up to 30 m long is the optimum solution. When the measuring instrument is inserted, the pump function starts automatically. The switch from diffusion to pump operation can be handled quickly and easily without tools or screws.

ERGONOMIC AND ROBUST
Thanks to its low weight and ergonomic design, the Dräger X-am 2500 offers a high degree of wearing comfort. The practical
 
two button control panel and easy menu navigation allow the instrument to be used intuitively, despite its comprehensive functionality. The integrated protective rubber coating and sensors that are not sensitive to shock provide additional safe- ty in case of impacts or vibrations. More- over, the Dräger X-am 2500 is not sensitive to electromagnetic radiation, e.g. from wireless devices. The Dräger X-am 2500 is water and dust resistant in accordance with protection class IP 67, so full func- tionality is guaranteed even if it falls into the water.
 
RELIABLE POWER SUPPLY

The Dräger X-am 2500 can operate with either alkaline batteries or with recharge- able NiMH batteries. This enables a reliab- le power supply for more than 12 hours, and with the high capacity battery pack more than 13 hours. Depending on the requirements, the batteries can be charged either in the workshop or in a vehicle. Operating time without Ex sensor is typi- cally more than 250 hours.

         
         
TECHNICAL DATA        
         
Dimensions   (W x H x D)48 x 130 x 44 mm
Weight   220 - 250 g
Ambient conditions Temperature -20 to +50 °C
  Pressure 700 to 1300 mbar
  Relative humidity 10 to 95 % r.h
Protection class   IP 67
Alarms Visual 360 °
  Audible Multi-tone > 90dB at 30cm
  Vibration  
Operating times   > 12 h with alkaline and NiMH,
    > 13 h with NiMH HC, > 250 h w/o Ex sensor with alkaline batteries
Charging time   < 4 h
Datalogger   Retrievable using an infrared interface > 1000 h with 4 gases at a recording interval
    of 1 value per minute
Approvals ATEX I M1 Ex ia I Ma, II 1G Ex ia IIC T3 Ga, I M2 Ex d ia I Mb, II 2G Ex d ia IIC T4/T3 Gb
    Performance approval to:
    EN 50104(2002)+A1(2004) O2
    EN 45544 CO & H2S
    EN 60079-29-1:2007 Methane to nonane
    EN 50271:2001 Software and documentation
  CSA (Canada & USA) Class I Div. 1 Group A, B, C, D T.-Code T4/T3
    A/Ex ia IIC T3 /Ga
    A/Ex d ia IIC T4/T3 /Gb
  IECEx Ex ia I Ma
    Ex ia IIC T3 Ga
    Ex d ia I Mb
    Ex d ia IIC T4/T3 Gb
  CE mark Electromagnetic Compatibility (Directive 2004/108/EC); ATEX (Directive 94/9/EC)
  MED Marine Equipment Directive (Directive 96/98/EC)
     

Back

 