Product Specifications |
|
|
PERFORMANCE |
Flow Range ........................400 – 1200 LPM |
|
|
Constant Flow Control .. ± 5% of set flow at 4-12 LPM |
|
|
Flow Compensation…….. Up to 5-hours at: |
|
4 LPM up to 67" H2O back pressure |
|
5 LPM up to 57" H2O back pressure |
|
6 LPM up to 48" H2O back pressure |
|
7 LPM up to 40" H2O back pressure |
|
8 LPM up to 33" H2O back pressure |
|
9 LPM up to 28" H2O back pressure |
|
10 LPM up to 23" H2O back pressure |
|
11 LPM up to 18" H2O back pressure |
|
12 LPM up to 14" H2O back pressure |
|
|
Run Time.............................8-hours minimum at: |
|
4 LPM up to 45" H2O back pressure |
|
5 LPM up to 38" H2O back pressure |
|
6 LPM up to 32" H2O back pressure |
|
7 LPM up to 27" H2O back pressure |
|
8 LPM up to 22" H2O back pressure |
|
9 LPM up to 18" H2O back pressure |
|
10 LPM up to 15" H2O back pressure |
|
11 LPM up to 12" H2O back pressure |
|
12 LPM up to 10" H2O back pressure |
|
|
Flow Fault...........................If flow changes exceed 5% within |
|
back pressure specifications, fault icon |
|
appears. If fault exceeds 30 saconds, |
|
pump shuts down. Pump attempts to |
|
restart every 3 minutes for up to 30 min. |
|
|
ENVIRONMENTAL |
Temperature Ranges |
Operating - 32°F to 113°F, Storage 4°F to 113°F |
Charging - 41°F to 104°F |
Humidity Ranges |
Operating - 0°F to 85°% RH, non-condensing |
Storage - 0°F to 98°% RH, non-condensing |
|
|
GENERAL |
|
Display - Flow Rate, Total Sample Time, Total Volume Sampled |
Controls - POWER/ENTER, SET/CAL, (up)/CLEAR,
(down)/RUN/STOP |
Indicators - Green LED ("Normal Operation") |
Icons (LCD) - Battery Indicator, Hold, Fault, Set, Prog |
Dimensions - 3.2W x 5.4H x 2.3D inches |
Weight - 19.5 oz |
|
|
ELECTICAL |
|
Battery Pack - Removable, Rechargeable Nickel-Metal-Hydride |
Battery Level Indicator - icon displays Full, Mid, & Low levels |
Interface Connectors - Charging Jack |
Charging Time - Under 4 hours |
|
|
APPRVALS / PERFORMENCE |
CE Mark 0518 |
|
|
|
|