Gloves
Respir

Cyclone Assembly, Dorr-Oliver Design 

 

This Dorr-Oliver cyclone is designed to separate the respirable fraction of airborne dust from the nonrespirable fraction. It consists of a two-stage cyclone and lightweight aluminum frame, which mounts a standard 2 or 3 piece 37mm filter cassette. When air enters the cyclone stage at 1.7 LPM (as recommended by NIOSH), the larger nonrespirable particles are centrifugally separated out and drop into a lower grit pot. The smaller, respirable particles pass onto the cassette, where they are captured by the filter membrane.

Dorr-Oliver Cyclone
40
 
10

Features:

  • Meets NIOSH requirements for 10mm nylon cyclones, as specified for nuisance dust (#0600) and silica dust (#7500, 7501, 7601, 7602)
  • For collection of all types of respirable dust
  • Durable, stainless steel/nylon design

Details
39
Product # 800061
Shipping Weight 1.00 lbs
U/M Each
Stock Status Normally Ships within 24 hours
 

Cyclone Calibration Jar 

The Cyclone Calibration Jar allows for the proper placement of the cyclone between the sampling pump and the calibration device.

Since cyclones only have one tubing connection, the only method of placing the cyclone in between the pump and calibrator is with the use of a chamber. This jar acts as a chamber.

1. To use, connect insert a cassette into the cyclone.
2. Then place the cyclone into the calibration jar.
3. Connect tubing from the pump to the jar lid and continue on to the cyclone.
4. Connect another piece of tubing from the jar to a primary calibrator

Cyclone Calibration Jar
38

Details
37
Product # 7013376
Shipping Weight 1.00 lbs
U/M Each
Stock Status Normally Ships within 24 hours
   

Zefon A-6 Bioaerosol Impactor 
A6 Single Stage Bioaerosol Impaction Sampler
36
 
The A6 is a single stage bioaerosol impaction sampler for the viable sampling of mold and fungi. An exact replica of the popular Andersen N-6 single stage sampler, this sampler is an aluminum device consisting of a top inlet "cone", a sampling head impacter stage which contains over 400 precision drilled holes and a base section which holds the agar media. The sampler is held together by three spring clamps and sealed with two o-ring gaskets. When air is drawn through the sampler, multiple jets of air direct any airborne particles toward the surface of the agar collection surface. Each A6 sampler undergoes stringent quality control standards by 2 independent firms. Performance tests indicate that there is no statistical difference between the Andersen N6 sampler and the A6. Features:
  • Proven technology for viable sampling
  • Identical to other single stage samplers, but for less cost
  • Uses standard petri dishes
  • Meets NIOSH Method 0800 and 0801 requirements
Specifications:
  • Required Flow Rate: 28.3 LPM (1 ACFM)
  • Particle Size Cut Point: .65 µm
  • Sampler Size: 4.25" diameter; 2.87" height; Weight 1.23 lbs
  • Material: Aircraft grade Aluminum
Required Equipment:
  • A6 Sampler
  • Pump capable of pulling up to 28.3 LPM
  • Pump rotameter calibrator
  • Tubing
  • Agar Sampling Media (supplied by laboratory
Details
35
Product # Z-A6
Shipping Weight 5.00 lbs
U/M Each
Stock Status Normally Ships within 24 hours
   

Zefon A-6 Bioaerosol Impactor Kit 

A6 Bioaerosol Impactor Kit is a complete kit with everything you need to begin sampling for viable mold and fungi with the A6 impactor (sampling media not included, supplied by laboratory)

A6 Kit Contents:

  • A6 Impactor Sampler
  • A rotary vane sampling pump
  • A tripod sampling stand for the A6 impactor
  • A pump flow meter
  • Tubing
  • A toolbox style carrying case
A6 Bioaerosol Impactor Kit
34
 
Details
33
Product # ZHV00-A6-KIT
Shipping Weight 24.00 lbs
U/M Each
Stock Status Normally Ships within 24 hours
   

A6 Impactor Calibration Adapter 
 
A6 Impactor Calibration Adapter
32
A6 Impactor Calibration Adapter connects onto the inlet cone of the A6 impactor to allow easy in-line calibration.
2

Example of proper calibration connection using the Z-A6 calibration adapter

Details
31
Product # Z-A6-CAL
Shipping Weight 4.00 lbs
U/M Each
Stock Status Normally Ships within 24 hours
   

A6 Impactor Tripod Stand 
 
A6 Impactor Tripod Stand
30

Details
29
Product # ZA0040
Shipping Weight 4.00 lbs
U/M Each
Stock Status Normally Ships within 24 hours
   

Bioisolation Filter 

 

An inline filter for use on area sampling pumps to filter out all particles not caputred by the sampler and prevent the pump from becoming contaminated. Compatible with all rotary vane and diaphragm pumps sold by R-Safe, each filter is 99.99% efficient in stopping bacterial and viral particles.
Inline Filter
28

Details
27
Product # ZA0045
Shipping Weight 0.20 lbs
U/M Each
Stock Status Normally Ships within 24 hours
   

Cassette Opener 

 

 

Heavy Duty Stainless Steel cassette opener. Works with 25mm, 37mm and Air-O-Cell cassettes. No need to remove labels, this opener cuts right through and effortlessly prys cassettes open.

Cassette Opener
26

Details
25
Product # ZA0046
Shipping Weight 1.00 lbs
U/M Each
Stock Status Normally Ships within 24 hours
   

Replacement Smoke Tubes 

 

Used to visually determine the directional pattern and velocity of air currents. It may also be used for HVAC, chemical laboratory or respirator fit testing.

Smoke Tubes
24

Details
23
Manufacturer Gastec Sensidyne
Product # 9501 5100
Shipping Weight 0.25 lbs 0.25 lbs
U/M Pack of 6 Pack of 10
Stock Status
Normally Ships within 24 hours
     

Smoke Tube Respirator Fit Test Kit 
Field proven as an OSHA accepted method since 1982, irritant smoke qualitative respirator fit testing is an economical, fast, safe and reliable fit testing method. Smoke tubes are used with a wide variety of respirators by firefighters, HAZMAT teams, first responders, the military and many industrial applications.

Irritant smoke testing is fast, simple, easy-to-perform and economical. You save money because there is no need for nebulizers, electric pumps, mixing jars, batteries, special test masks, mask probes or testing hoods. Each kit has everything you need for over 50 tests without the cost of extra equipment. Plus, you save time because each smoke tube and aspiration bulb pump is pre-calibrated and ready for immediate use. No warm up time or calibration required.
Irritant Smoke Respirator Fit Test Kit
22

 

Each kit comes complete with 6 smoke tubes, rubber tube caps, aspirator bulb and carrying case.

Details
21
Product # 500
Shipping Weight 0.75 lbs
U/M Each
Stock Status Normally Ships within 24 hours
   

Bitrex Respirator Fit Test Kit 

 

The Bitrex® Fit Test Kit offers qualitative OSHA-compliant fit testing for disposable and reusable dust and mist respirators. Bitrex creates an unmistakable bitter taste that indicates break through in the respirator fit. Bitrex has been found safer than saccharin tests while producing identical results. Disposable glass ampules make pouring solution into nebulizers easier and reduces the chance of contamination.

Bitrex® Respirator Fit Test Kit
20

Features:
  • For testing the facepiece-to-face seal
  • Fast, easy method for performing qualitative fit testing
  • Use with any particulate respirator or any gas/vapor respirator with particulate prefilter
  • Helps satisfy respiratory program requirements
  • Can be used during respirator training programs
  • Helps meet administrative respiratory protection training program regulations as specified in OSHA 29 CFR 1910.134

Each kit comes complete with hood, 2 nebulizers, fit test solution, sensitiveity solution and instructions



Details
19
Product # 2041
Shipping Weight 5.00 lbs
U/M Each
Stock Status Normally Ships within 24 hours
   

Tyvek Suits with Hood 

 

Practically anywhere in industry, Tyvek® spunbonded olefin by DuPont has been hailed for years. It has served reliably as the unique material that imparts high strength, flexibility, durability, great barrier qualities and wearer comfort to protective clothing. Tyvek® by DuPont improves the great protective features previous generations offered. Superior barrier, durability and breathability leave competitive materials far behind.

Tyvek® Protective Clothing
18

Details
17
Garment
Style
Size
Part #
Pieces per Case
lbs/case
Coverall Plain
M-XL
TY14120
25
8
 
Coverall Elastic/Wrist/Ankles
M-XL
TY14125
25
8
 
Coverall Hood/Elastic/Wrist/Ankles
M-XL
TY14127
25
10
 
Coverall Hood/Elastic/Wrist/Ankles/Feet
M-XL
TY14261
25
10
 
Shoe Covers Elastic/Ankles
UNISZ
TY14440
100
8
 

back

  Copyright © 2016 R-Safe  |  Designed by Srcreationz.com | Privacy Policy