Click
on the picture for more information Call for
pricing |
|
|
|
|
|
|
|
|
|
Pump
Model |
|
|
|
|
|
|
|
|
|
Flow
Range, cc/min |
200-800 |
5-10
LPM |
4-12
LPM |
1-5,000 |
20-5,000* |
1-3,000* |
1-5,000* |
1-350 |
500-3,000 |
Constant
Flow |
Yes |
Yes |
Yes |
450-5,000
cc/min |
Yes |
Yes |
Yes |
Yes |
|
Constant
Low Flow, cc/min |
Yes |
|
|
20-449
cc/min |
|
Yes
1-500* |
Yes
1-500* |
Yes |
|
Programmable
Timer Option |
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
|
|
Multiflow
Capability, cc/min |
No |
No |
No |
Yes |
Yes
20-750*** |
Yes
1-750*** |
Yes
1-750*** |
Yes |
|
|
All
Digital Gilian pump, offering LCD display
of live flow rate, total sample time, and total volume
sampled. Intuitive four botton operation makes this
low flow pump extremely easy to use. Extraordinary
back preasures. |
All
Digital Gilian pump, offering LCD display
of live flow rate, total sample time, and total volume
sampled. Intuitive four botton operation makes this
pump extremely easy to use for a high flow LPM pump. |
All
Digital Gilian pump, offering LCD display
of live flow rate, total sample time, and total volume
sampled. Intuitive four botton operation makes this
pump extremely easy to use for a high flow LPM pump. |
All Digital Gilian
pump with selectable high flow or low flow switch. Three
models to choose from including mode correcting for
temperature and barometric pressure. |
All
Digital Gilian pump, offering LCD display
of live flow rate, total sample time, and total
volume sampled. Intuitive four botton operation
makes this pump extremely easy to use. Extraordinary
back preasures. Suitable for use with all collection
media types.
|
Full
Featured model offers most complete set
of features and options, including a programmable
timer. Suitable for use with all collection media
types.
|
High
Flow Pump is similar in features to GilAir
3, except ot has a double diaphragm pump and a
larger capacity battery to handle higher flow rates.
|
Compact
Low Flow pump is designed for very low
flow requirements. Also offers constant pressure,
ideal for single or multible sorbent tube use.
Small size easily fits in shirt pocket.
|
Lead
and Asbestos sampler combines "no
frills" with low cost. Rugged construction
with-stands the toughest environments. Meets
NIOSH 7400 for asbestos & 7082. 7105 and
7300 for lead.
|
High
Flow Range
(flow
control +/-5% of set point, except model BDX-II) |
200-800cc/min |
5.00-10.00
LPM |
4.00-12.00
LPM |
450-5,000 cc/min to
30" H2O |
800-5,000cc/min
0.7-3.5
LPM |
850-3,000cc/min
0.85-3.0
LPM |
850-5,000cc/min
0.85-5.0
LPM |
1-350cc/min
0.001-0.35LPM |
500-3,000cc/min
0.5-3.0
LPM |
Low
Flow Range, Constant Pressure
(Multi
Flow) |
200-800cc/min |
Not
Happening With This Pump |
Not
Happening With This Pump
|
|
20-750
cc/min
with
Low Flow Adapter |
1-500cc/min,
to 25" (640mm) H2O* |
1-500cc/min,
to 25" (640mm) H2O* |
1-200cc/min,
to 25" (640mm) H2O |
N/A |
Max.
Pressure Capability: |
See Spec Sheet |
See
Spec Sheet |
See
Spec Sheet |
Fault† |
8
hr. Run†† |
Fault† |
8
hr. Run†† |
Fault† |
8
hr. Run†† |
Fault† |
8
hr. Run†† |
Fault† |
8
hr. Run†† |
Fault† |
8
hr. Run†† |
@
0.75 LPM, inches H2O |
|
|
|
|
|
|
40 |
40 |
_ |
_ |
_ |
_ |
_ |
_ |
NA |
NA |
|
|
@
1 LPM, inches H2O |
|
|
|
|
|
|
40 |
35 |
|
70 |
30 |
25 |
37 |
29 |
NA |
NA |
|
|
@
2 LPM, inches H2O |
|
|
|
|
|
|
40 |
30 |
_ |
60 |
- |
- |
37 |
26 |
NA |
NA |
|
|
@
2.5 LPM, inches H2O |
|
|
|
|
|
|
37 |
30 |
|
- |
20 |
15 |
_ |
_ |
NA |
NA |
_ |
20 |
@
3 LPM, inches H2O |
|
|
|
|
|
|
35 |
30 |
|
50 |
10 |
8 |
10 |
8 |
NA |
NA |
|
|
@
3.5 LPM, inches H2O |
|
|
|
|
|
|
32 |
25 |
_ |
_ |
_ |
_ |
_ |
_ |
NA |
NA |
|
|
@
4 LPM, inches H2O |
|
|
|
|
|
|
30 |
20 |
_ |
30 |
- |
- |
20 |
18 |
NA |
NA |
|
|
@
5 LPM, inches H2O |
|
|
|
|
|
|
15 |
12 |
_ |
20 |
- |
- |
10 |
8 |
NA |
NA |
|
|
Data
Shown in Display |
Live
Flow Rate, Total Sample Time, Total Volume Sampled,
Low Battery |
Live
Flow Rate, Total Sample Time, Total Volume Sampled,
Low Battery |
Live
Flow Rate, Total Sample Time, Total Volume Sampled,
Low Battery |
Flow
Rate, Sample Time,Battery Level, Run Time, Predicted
Run Time, Sampling Mode, Time and Date, Sample Volume
in Actual Conditions. |
Live
Flow Rate, Total Sample Time, Total Volume Sampled,
Low Battery |
Elapsed
Time (clock & Timer models) Low Battery, Flow Fault |
Elapsed
Time (clock & Timer models) Low Battery, Flow Fault |
Elapsed
Time |
NA |
Overall
Dimensions inches: |
3.2Wx5.4Hx2.3D |
3.2Wx5.4Hx2.3D |
3.2Wx5.4Hx2.3D |
4.3Wx2.4Hx2.4D |
3.2Wx5.4Hx2.3D |
3.6Wx3.9Hx2.0D |
3.6Wx3.9Hx2.0D |
2.5Wx4.63Hx1.38D |
3.6Wx3.9Hx2.0D |
Total
Pump Weight |
20.5
oz. |
20.5
oz. |
19.5
oz. |
20.5
oz. |
20.5
oz. |
21.0
oz. |
22.5
oz. |
12
oz. |
21
oz. |
Rechargeable
Battery |
(NiMH)
Memory-Free |
(NiMH)
Memory-Free |
(NiMH)
Memory-Free |
7.2V,
NiMH |
(NiMH)
Memory-Free |
4.8v,
1.8 amphr. (NiCad) |
6.0v,
1.8 amphr. (NiCad) |
4.8v,
0.5 amphr. (NiCad), (NiMH) Available |
4.8v,
1.8 amphr. (NiCad) |
Operating
Temperature Limitations |
32
to 113 F |
32
to 113 F |
32
to 113 F |
32
to 113 F |
32
to 113 F |
32
to 104 F |
32
to 104 F |
-4
to 113 F |
-4
to 113 F |
Certifications |
FM, CE/ATEX |
FM, CE/ATEX |
CE Mark 0518 |
FM,
CE/ATEX, IECEx |
FM &CE |
CE,
Ex,UL: Class I, Group A, B, C, D; Class II,E, F, G;
and Class III; DIV. 1; Temp. Code T3C**** |
UL |
Charging
Time |
<
4 hours |
<
4 hours |
<
4 hours |
<3.5
hours |
<
5 hours |
14
- 16 hours |
Battery
Life††† |
300
- 500 charge-recharge cycles, or 2.5 yrs with <20
hrs/ weekly use, 1.5-2.5 yrs (20-39 hrs. weekly use),1.0-1.5
yrs (40-60 hrs.weekly use) |
Operating
Duration (full Charge) |
8 hour minimum |
8
hour minimum (See
Spec Sheet) |
8
hour minimum |
8
to 10 hrs. at 3.0 LPM (see back pressure, above) (except
BDX II, rated at 10 hrs. @ 2.0 LPM) |
|
*
Requires attachment of optional Low Flow Module
**
Constant pressure low flow of 1 to 750 cc/min requires
HFS-513AU model, which has capability built into
pump.
***
Requires attachment of Multiflow Constant Pessure
Module, allowing manifolding of multiple sorbent
tubes to sample for several gasses simultaneously. |
† Maximum
backpressure before fualt with fully charged battery
pack
†† Safe
backpressure for 8-hour run without fault.
††† Battery
Life estimates based on proper battery maintenance. |